网站首页
IC库存
IC展台
电子资讯
技术资料
PDF文档
我的博客
IC72论坛
ic72 logo
资料首页最新产品 技术参数 电路图 设计应用 解决方案 代理商查询 IC替换 IC厂商 电子辞典
关键字: 技术文章 PDF资料 IC价格 电路图 代理商查询 IC替换 IC厂商 电子辞典

模块化的防盗系统

本电路图所用到的元器件:

4001 BC547

This circuit features automatic Exit and Entry delays and a timed Bell Cut-off. It has provision for both normally-closed and normally-open contacts, and a 24-hour Personal Attack/Tamper zone. It is connected permanently to the 12-volt supply and its operation is "enabled" by opening SW1. By using the expansion modules, you can add as many zones as you require; some or all of which may be the inertia (shock) sensor type. All the green LEDs should be lighting before you open SW1. You then have up to about a minute to leave the building. As you do so, the Buzzer will sound. It should stop sounding when you shut the door behind you. This indicates that the Exit/Entry loop has been successfully restored within the time allowed. When you re-enter the building you have up to about a minute to move SW1 to the off position. If SW1 is not switched off in time, the relay will energise and sound the main bell. It will ring for up to about 40 minutes. But it can be turned off at any time by SW1. The "Instant" zone has no Entry Delay. If you don't want to use N/O switches, leave out R8, C8 and Q2; and fit a link between Led 3 and C7. The 24 Hour PA/Tamper protection is provided by the SCR/Thyristor. If any of the switches in the N/C loop is opened, R11 will trigger the SCR and the bell will ring. In this case the bell has no time limit. Once the loop is closed again, the SCR may be reset by pressing SW2 and temporarily interrupting the current flow. The basic circuit will be satisfactory in many situations. However, it's much easier to find a fault when the alarm is divided into zones and the control panel can remember which zone has caused the activation. The expansion modules are designed to do this. Although they will work with the existing instant zone, they are intended to replace it. When a zone is activated, its red LED will light and remain lit until the reset button is pressed. All the modules can share a single reset button. The Stripboard layout of the prototype is available.

ImgLoad(document.getElementById("BodyLabel"));

热门搜索:2986122 LS606M SBB830-QTY10 PM6SN1 SBB830 6SPDX-15 8300SB1 SUPER6OMNI D SS240806 2856087 2866666 2838228 TLP602 BT05-F250H-03 02T5000JF 02T1001JF 2920078 2882828 ULTRABLOK RS1215-RA 2920120 UL17CB-15 6SPDX BT137S-500E PS-415-HG
COPYRIGHT:(1998-2010) IC72 达普IC芯片交易网
客户服务:service@IC72.com 库存上载:IC72@IC72.com
(北京)联系方式: 在线QQ咨询:点击这里给我发消息 联系电话:010-82614113 传真:010-82614123
京ICP备06008810号-21 京公网安备 11010802032910 号 企业资质